1<!-- $Id$ -->
2
3<chapter>
4  <title id="filter">PyKota's internals</title>
5 
6  <para>Last modified on $Date$</para>
7 
8  <para>
9    To account for pages or eventually ink usage
10    <footnote>
11      <para>
12        PyKota doesn't currently account for ink usage, it only accounts
13        pages. To account for ink usage, you should use PrintBill instead for now.
14      </para> 
15    </footnote> 
16    , you must plug your accounting
17    system somewhere into the printing system you use, be it either <application>CUPS</application>
18    or <application>LPRng</application>. One way to do this without having
19    to modify the printing system itself, is by using a <firstterm>filter</firstterm>.
20  </para>
21 
22  <para>
23    A filter is a computer program which takes data in one format as its input, and outputs the
24    same data but transformed into another format. <application>CUPS</application> already
25    contains many filters. For example there's one filter named <filename>pstops</filename> which accepts
26    PostScript data as its input, and, as its name implies, outputs PostScript data too, but after having
27    eventually rearranged the pages to fit several pages on a single sheet of paper, or other manipulations
28    like that. <application>LPRng</application> also contains several filters like this.
29  </para>
30 
31  <para>
32    The <filename>pstops</filename> filter described above is also in charge of doing basic page
33    accounting, but <application>PyKota</application> currently doesn't use this facility since it may
34    prove to be unreliable depending on the drivers used or if a paper jam occurs for example.
35  </para>
36 
37  <para>
38    <application>LPRng</application> can also use filters, often used in combination with
39    <application>LPRng</application> are <application>magicfilter</application> which can convert
40    different input formats to native printers languages like PostScript or ESC/P2 and
41    <application>ifhp</application> which can do low-level accounting.
42  </para> 
43 
44  <para>
45    So to do its own accounting, <application>PyKota</application> has its own filters, for <application>CUPS</application>
46    it's named <filename>cupspykota</filename>, which is in fact a <application>CUPS</application> backends wrapper,
47    and for <application>LPRng</application> it's named <filename>lprngpykota</filename>, as you have probably guessed.
48    The procedure to plug the correct filter into your printing system is described in the
49    <xref linkend="installation" endterm="installation"> chapter.
50  </para>
51 
52  <para>
53    Currently with a <application>CUPS</application> internal accounting mechanism, the <filename>pstops</filename>
54    filter can be bypassed. That's why <application>PyKota</application> uses its own backend.
55    The <filename>cupspykota</filename> backend wrapper ensures that jobs can't bypass it, so you can use
56    any printer with any driver and any command line option, and you can be sure that your
57    print job will be correctly accounted for.
58  </para>
59 
60  <para>
61    When using the <literal>hardware</literal> accounting method,
62    <application>PyKota</application> launches the script you specified to
63    ask the printer for its internal page counter at the start and at the end of the print job, and
64    computes the values' difference to know the job's size.
65  </para>
66 
67  <para>
68    When using the <literal>software</literal> accounting method,
69    the command you specified is launched with the job's data on its
70    standard input. Your command must print the job's size in number of
71    pages on a single line on its standard output. This number is then
72    read by <application>PyKota</application> and used to update the current user's quota information.
73  </para>
74 
75  <para>
76    If a problem occurs, it is logged either to the filter's standard error or to the system logger, depending on
77    your preferences in <application>PyKota</application>'s configuration files. Also if a print quota is reached
78    you may choose if the administrator, the user, both or no-one will receive an email message explaining
79    the situation and proposing a solution. You can even configure another action instead of sending email
80    messages if you want.
81  </para>
82 
83</chapter>