[1475] | 1 | # PyKota |
---|
| 2 | # -*- coding: ISO-8859-15 -*- |
---|
| 3 | # |
---|
| 4 | # PyKota - Print Quotas for CUPS and LPRng |
---|
| 5 | # |
---|
| 6 | # (c) 2003-2004 Jerome Alet <alet@librelogiciel.com> |
---|
| 7 | # This program is free software; you can redistribute it and/or modify |
---|
| 8 | # it under the terms of the GNU General Public License as published by |
---|
| 9 | # the Free Software Foundation; either version 2 of the License, or |
---|
| 10 | # (at your option) any later version. |
---|
| 11 | # |
---|
| 12 | # This program is distributed in the hope that it will be useful, |
---|
| 13 | # but WITHOUT ANY WARRANTY; without even the implied warranty of |
---|
| 14 | # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
---|
| 15 | # GNU General Public License for more details. |
---|
| 16 | # |
---|
| 17 | # You should have received a copy of the GNU General Public License |
---|
| 18 | # along with this program; if not, write to the Free Software |
---|
| 19 | # Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307, USA. |
---|
| 20 | # |
---|
| 21 | # $Id$ |
---|
| 22 | # |
---|
| 23 | # $Log$ |
---|
[2075] | 24 | # Revision 1.36 2005/02/20 22:58:55 jalet |
---|
| 25 | # Added some informations from RFC3805 and RFC2790 |
---|
| 26 | # |
---|
[2027] | 27 | # Revision 1.35 2005/01/12 22:44:06 jalet |
---|
| 28 | # Tried to fix a problem with printers which are slow to pass into printing mode. |
---|
| 29 | # |
---|
[1949] | 30 | # Revision 1.34 2004/11/19 11:57:51 jalet |
---|
| 31 | # Modified the SNMP fix as hinted by pysnmp's maintainer |
---|
| 32 | # |
---|
[1948] | 33 | # Revision 1.33 2004/11/19 10:35:37 jalet |
---|
| 34 | # Catches TypeMismatchError in SNMP answer handling code |
---|
| 35 | # |
---|
[1933] | 36 | # Revision 1.32 2004/11/16 23:23:40 jalet |
---|
| 37 | # Fixed internal PJL handling wrt the 35078 PowerSave mode. |
---|
| 38 | # |
---|
[1896] | 39 | # Revision 1.31 2004/11/01 14:32:26 jalet |
---|
| 40 | # Fix for unneeded out of band status in pjl_over_tcp/9100 |
---|
| 41 | # |
---|
[1775] | 42 | # Revision 1.30 2004/10/05 09:21:34 jalet |
---|
| 43 | # Removed misleading comments |
---|
| 44 | # |
---|
[1774] | 45 | # Revision 1.29 2004/10/05 09:20:07 jalet |
---|
| 46 | # Reduced delay from 2 to 1 seconds in internal SNMP and PJL_over_TCP |
---|
| 47 | # handlers |
---|
| 48 | # |
---|
[1749] | 49 | # Revision 1.28 2004/09/27 20:09:30 jalet |
---|
| 50 | # Lowered timeout delay for PJL queries |
---|
| 51 | # |
---|
[1748] | 52 | # Revision 1.27 2004/09/27 20:00:35 jalet |
---|
| 53 | # Typo |
---|
| 54 | # |
---|
[1746] | 55 | # Revision 1.26 2004/09/27 19:56:27 jalet |
---|
| 56 | # Added internal handling for PJL queries over port tcp/9100. Now waits |
---|
| 57 | # for printer being idle before asking, just like with SNMP. |
---|
| 58 | # |
---|
[1745] | 59 | # Revision 1.25 2004/09/27 09:21:37 jalet |
---|
| 60 | # Now includes printer's hostname in SNMP error messages |
---|
| 61 | # |
---|
[1743] | 62 | # Revision 1.24 2004/09/24 21:19:48 jalet |
---|
| 63 | # Did a pass of PyChecker |
---|
| 64 | # |
---|
[1739] | 65 | # Revision 1.23 2004/09/23 19:18:12 jalet |
---|
| 66 | # Now loops when the external hardware accounter fails, until it returns a correct value |
---|
| 67 | # |
---|
[1737] | 68 | # Revision 1.22 2004/09/22 19:48:01 jalet |
---|
| 69 | # Logs the looping message as debug instead of as info |
---|
| 70 | # |
---|
[1736] | 71 | # Revision 1.21 2004/09/22 19:27:41 jalet |
---|
| 72 | # Bad import statement |
---|
| 73 | # |
---|
[1735] | 74 | # Revision 1.20 2004/09/22 19:22:27 jalet |
---|
| 75 | # Just loop in case a network error occur |
---|
| 76 | # |
---|
[1734] | 77 | # Revision 1.19 2004/09/22 14:29:01 jalet |
---|
| 78 | # Fixed nasty typo |
---|
| 79 | # |
---|
[1732] | 80 | # Revision 1.18 2004/09/21 16:00:46 jalet |
---|
| 81 | # More informational messages |
---|
| 82 | # |
---|
[1730] | 83 | # Revision 1.17 2004/09/21 13:42:18 jalet |
---|
| 84 | # Typo |
---|
| 85 | # |
---|
[1729] | 86 | # Revision 1.16 2004/09/21 13:30:53 jalet |
---|
| 87 | # First try at full SNMP handling from the Python code. |
---|
| 88 | # |
---|
[1715] | 89 | # Revision 1.15 2004/09/14 11:38:59 jalet |
---|
| 90 | # Minor fix |
---|
| 91 | # |
---|
[1714] | 92 | # Revision 1.14 2004/09/14 06:53:53 jalet |
---|
| 93 | # Small test added |
---|
| 94 | # |
---|
[1713] | 95 | # Revision 1.13 2004/09/13 16:02:45 jalet |
---|
| 96 | # Added fix for incorrect job's size when hardware accounting fails |
---|
| 97 | # |
---|
[1703] | 98 | # Revision 1.12 2004/09/06 15:42:34 jalet |
---|
| 99 | # Fix missing import statement for the signal module |
---|
| 100 | # |
---|
[1687] | 101 | # Revision 1.11 2004/08/31 23:29:53 jalet |
---|
| 102 | # Introduction of the new 'onaccountererror' configuration directive. |
---|
| 103 | # Small fix for software accounter's return code which can't be None anymore. |
---|
| 104 | # Make software and hardware accounting code look similar : will be factorized |
---|
| 105 | # later. |
---|
| 106 | # |
---|
[1685] | 107 | # Revision 1.10 2004/08/27 22:49:04 jalet |
---|
| 108 | # No answer from subprocess now is really a fatal error. Waiting for some |
---|
| 109 | # time to make this configurable... |
---|
| 110 | # |
---|
[1680] | 111 | # Revision 1.9 2004/08/25 22:34:39 jalet |
---|
| 112 | # Now both software and hardware accounting raise an exception when no valid |
---|
| 113 | # result can be extracted from the subprocess' output. |
---|
| 114 | # Hardware accounting now reads subprocess' output until an integer is read |
---|
| 115 | # or data is exhausted : it now behaves just like software accounting in this |
---|
| 116 | # aspect. |
---|
| 117 | # |
---|
[1624] | 118 | # Revision 1.8 2004/07/22 22:41:48 jalet |
---|
| 119 | # Hardware accounting for LPRng should be OK now. UNTESTED. |
---|
| 120 | # |
---|
[1600] | 121 | # Revision 1.7 2004/07/16 12:22:47 jalet |
---|
| 122 | # LPRng support early version |
---|
| 123 | # |
---|
[1584] | 124 | # Revision 1.6 2004/07/01 19:56:42 jalet |
---|
| 125 | # Better dispatching of error messages |
---|
| 126 | # |
---|
[1536] | 127 | # Revision 1.5 2004/06/10 22:42:06 jalet |
---|
| 128 | # Better messages in logs |
---|
| 129 | # |
---|
[1495] | 130 | # Revision 1.4 2004/05/24 22:45:49 jalet |
---|
| 131 | # New 'enforcement' directive added |
---|
| 132 | # Polling loop improvements |
---|
| 133 | # |
---|
[1494] | 134 | # Revision 1.3 2004/05/24 14:36:40 jalet |
---|
| 135 | # Revert to old polling loop. Will need optimisations |
---|
| 136 | # |
---|
[1483] | 137 | # Revision 1.2 2004/05/18 14:49:22 jalet |
---|
| 138 | # Big code changes to completely remove the need for "requester" directives, |
---|
| 139 | # jsut use "hardware(... your previous requester directive's content ...)" |
---|
| 140 | # |
---|
[1475] | 141 | # Revision 1.1 2004/05/13 13:59:30 jalet |
---|
| 142 | # Code simplifications |
---|
| 143 | # |
---|
| 144 | # |
---|
| 145 | # |
---|
| 146 | |
---|
| 147 | import os |
---|
[1746] | 148 | import socket |
---|
[1729] | 149 | import time |
---|
[1703] | 150 | import signal |
---|
[1483] | 151 | import popen2 |
---|
[1729] | 152 | |
---|
[1475] | 153 | from pykota.accounter import AccounterBase, PyKotaAccounterError |
---|
| 154 | |
---|
[1774] | 155 | ITERATIONDELAY = 1.0 # 1 Second |
---|
[1749] | 156 | STABILIZATIONDELAY = 3 # We must read three times the same value to consider it to be stable |
---|
| 157 | |
---|
[1729] | 158 | try : |
---|
[1948] | 159 | from pysnmp.asn1.encoding.ber.error import TypeMismatchError |
---|
[1736] | 160 | from pysnmp.mapping.udp.error import SnmpOverUdpError |
---|
[1729] | 161 | from pysnmp.mapping.udp.role import Manager |
---|
| 162 | from pysnmp.proto.api import alpha |
---|
| 163 | except ImportError : |
---|
| 164 | hasSNMP = 0 |
---|
| 165 | else : |
---|
| 166 | hasSNMP = 1 |
---|
[2075] | 167 | pageCounterOID = ".1.3.6.1.2.1.43.10.2.1.4.1.1" # SNMPv2-SMI::mib-2.43.10.2.1.4.1.1 |
---|
| 168 | hrPrinterStatusOID = ".1.3.6.1.2.1.25.3.5.1.1.1" # SNMPv2-SMI::mib-2.25.3.5.1.1.1 |
---|
[1729] | 169 | printerStatusValues = { 1 : 'other', |
---|
| 170 | 2 : 'unknown', |
---|
| 171 | 3 : 'idle', |
---|
| 172 | 4 : 'printing', |
---|
| 173 | 5 : 'warmup', |
---|
| 174 | } |
---|
[2075] | 175 | hrDeviceStatusOID = ".1.3.6.1.2.1.25.3.2.1.5.1" # SNMPv2-SMI::mib-2.25.3.2.1.5.1 |
---|
| 176 | deviceStatusValues = { 1 : 'unknown', |
---|
| 177 | 2 : 'running', |
---|
| 178 | 3 : 'warning', |
---|
| 179 | 4 : 'testing', |
---|
| 180 | 5 : 'down', |
---|
| 181 | } |
---|
| 182 | hrPrinterDetectedErrorStateOID = ".1.3.6.1.2.1.25.3.5.1.2.1" # SNMPv2-SMI::mib-2.25.3.5.1.2.1 |
---|
| 183 | prtConsoleDisplayBufferTextOID = ".1.3.6.1.2.1.43.16.5.1.2.1.1" # SNMPv2-SMI::mib-2.43.16.5.1.2.1.1 |
---|
[1729] | 184 | |
---|
[2075] | 185 | # |
---|
| 186 | # Documentation taken from RFC 3805 (Printer MIB v2) and RFC 2790 (Host Resource MIB) |
---|
| 187 | # |
---|
| 188 | # TODO : if hrDeviceStatus==2 and hrPrinterStatus==1 then it's powersave mode. |
---|
| 189 | # |
---|
[1729] | 190 | class SNMPAccounter : |
---|
| 191 | """A class for SNMP print accounting.""" |
---|
| 192 | def __init__(self, parent, printerhostname) : |
---|
| 193 | self.parent = parent |
---|
| 194 | self.printerHostname = printerhostname |
---|
| 195 | self.printerInternalPageCounter = self.printerStatus = None |
---|
| 196 | |
---|
| 197 | def retrieveSNMPValues(self) : |
---|
| 198 | """Retrieves a printer's internal page counter and status via SNMP.""" |
---|
| 199 | ver = alpha.protoVersions[alpha.protoVersionId1] |
---|
| 200 | req = ver.Message() |
---|
| 201 | req.apiAlphaSetCommunity('public') |
---|
| 202 | req.apiAlphaSetPdu(ver.GetRequestPdu()) |
---|
[2075] | 203 | req.apiAlphaGetPdu().apiAlphaSetVarBindList((pageCounterOID, ver.Null()), \ |
---|
| 204 | (hrPrinterStatusOID, ver.Null())) |
---|
[1729] | 205 | tsp = Manager() |
---|
| 206 | try : |
---|
| 207 | tsp.sendAndReceive(req.berEncode(), (self.printerHostname, 161), (self.handleAnswer, req)) |
---|
[1949] | 208 | except SnmpOverUdpError, msg : |
---|
[1745] | 209 | self.parent.filter.printInfo(_("Network error while doing SNMP queries on printer %s : %s") % (self.printerHostname, msg), "warn") |
---|
[1729] | 210 | tsp.close() |
---|
| 211 | |
---|
[1743] | 212 | def handleAnswer(self, wholeMsg, notusedhere, req): |
---|
[1729] | 213 | """Decodes and handles the SNMP answer.""" |
---|
[1949] | 214 | self.parent.filter.logdebug("SNMP message : '%s'" % repr(wholeMsg)) |
---|
[1729] | 215 | ver = alpha.protoVersions[alpha.protoVersionId1] |
---|
| 216 | rsp = ver.Message() |
---|
[1949] | 217 | try : |
---|
| 218 | rsp.berDecode(wholeMsg) |
---|
| 219 | except TypeMismatchError, msg : |
---|
| 220 | self.parent.filter.printInfo(_("SNMP message decoding error for printer %s : %s") % (self.printerHostname, msg), "warn") |
---|
| 221 | else : |
---|
| 222 | if req.apiAlphaMatch(rsp): |
---|
| 223 | errorStatus = rsp.apiAlphaGetPdu().apiAlphaGetErrorStatus() |
---|
| 224 | if errorStatus: |
---|
| 225 | self.parent.filter.printInfo(_("Problem encountered while doing SNMP queries on printer %s : %s") % (self.printerHostname, errorStatus), "warn") |
---|
| 226 | else: |
---|
| 227 | self.values = [] |
---|
| 228 | for varBind in rsp.apiAlphaGetPdu().apiAlphaGetVarBindList(): |
---|
| 229 | self.values.append(varBind.apiAlphaGetOidVal()[1].rawAsn1Value) |
---|
| 230 | try : |
---|
| 231 | # keep maximum value seen for printer's internal page counter |
---|
| 232 | self.printerInternalPageCounter = max(self.printerInternalPageCounter, self.values[0]) |
---|
| 233 | self.printerStatus = self.values[1] |
---|
| 234 | except IndexError : |
---|
| 235 | pass |
---|
| 236 | else : |
---|
| 237 | return 1 |
---|
[1729] | 238 | |
---|
| 239 | def waitPrinting(self) : |
---|
| 240 | """Waits for printer status being 'printing'.""" |
---|
| 241 | while 1: |
---|
| 242 | self.retrieveSNMPValues() |
---|
| 243 | statusAsString = printerStatusValues.get(self.printerStatus) |
---|
[2027] | 244 | if statusAsString in ('printing',) : |
---|
[1729] | 245 | break |
---|
[2027] | 246 | self.parent.filter.logdebug(_("Waiting for printer %s to be printing...") % self.parent.filter.printername) |
---|
[1749] | 247 | time.sleep(ITERATIONDELAY) |
---|
[1729] | 248 | |
---|
| 249 | def waitIdle(self) : |
---|
| 250 | """Waits for printer status being 'idle'.""" |
---|
| 251 | idle_num = idle_flag = 0 |
---|
| 252 | while 1 : |
---|
| 253 | self.retrieveSNMPValues() |
---|
| 254 | statusAsString = printerStatusValues.get(self.printerStatus) |
---|
| 255 | idle_flag = 0 |
---|
| 256 | if statusAsString in ('idle',) : |
---|
| 257 | idle_flag = 1 |
---|
| 258 | if idle_flag : |
---|
| 259 | idle_num += 1 |
---|
| 260 | if idle_num > STABILIZATIONDELAY : |
---|
| 261 | # printer status is stable, we can exit |
---|
| 262 | break |
---|
| 263 | else : |
---|
| 264 | idle_num = 0 |
---|
[1739] | 265 | self.parent.filter.logdebug(_("Waiting for printer %s's idle status to stabilize...") % self.parent.filter.printername) |
---|
[1749] | 266 | time.sleep(ITERATIONDELAY) |
---|
[1746] | 267 | |
---|
[1896] | 268 | pjlMessage = "\033%-12345X@PJL USTATUSOFF\r\n@PJL INFO STATUS\r\n@PJL INFO PAGECOUNT\r\n\033%-12345X" |
---|
[1746] | 269 | pjlStatusValues = { |
---|
| 270 | "10000" : "Powersave Mode", |
---|
| 271 | "10001" : "Ready Online", |
---|
| 272 | "10002" : "Ready Offline", |
---|
| 273 | "10003" : "Warming Up", |
---|
| 274 | "10004" : "Self Test", |
---|
| 275 | "10005" : "Reset", |
---|
| 276 | "10023" : "Printing", |
---|
[1933] | 277 | "35078" : "Powersave Mode", # 10000 is ALSO powersave !!! |
---|
[1746] | 278 | } |
---|
| 279 | class PJLAccounter : |
---|
| 280 | """A class for PJL print accounting.""" |
---|
| 281 | def __init__(self, parent, printerhostname) : |
---|
| 282 | self.parent = parent |
---|
| 283 | self.printerHostname = printerhostname |
---|
| 284 | self.printerInternalPageCounter = self.printerStatus = None |
---|
| 285 | self.printerInternalPageCounter = self.printerStatus = None |
---|
| 286 | self.timedout = 0 |
---|
| 287 | |
---|
| 288 | def alarmHandler(self, signum, frame) : |
---|
| 289 | """Query has timedout, handle this.""" |
---|
| 290 | self.timedout = 1 |
---|
| 291 | raise IOError, "Waiting for PJL answer timed out. Please try again later." |
---|
| 292 | |
---|
| 293 | def retrievePJLValues(self) : |
---|
| 294 | """Retrieves a printer's internal page counter and status via PJL.""" |
---|
| 295 | port = 9100 |
---|
| 296 | sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM) |
---|
| 297 | try : |
---|
| 298 | sock.connect((self.printerHostname, port)) |
---|
| 299 | except socket.error, msg : |
---|
| 300 | self.parent.filter.printInfo(_("Problem during connection to %s:%s : %s") % (self.printerHostname, port, msg), "warn") |
---|
| 301 | else : |
---|
| 302 | try : |
---|
| 303 | sock.send(pjlMessage) |
---|
| 304 | except socket.error, msg : |
---|
| 305 | self.parent.filter.printInfo(_("Problem while sending PJL query to %s:%s : %s") % (self.printerHostname, port, msg), "warn") |
---|
| 306 | else : |
---|
| 307 | actualpagecount = self.printerStatus = None |
---|
| 308 | self.timedout = 0 |
---|
[1748] | 309 | while (self.timedout == 0) or (actualpagecount is None) or (self.printerStatus is None) : |
---|
[1746] | 310 | signal.signal(signal.SIGALRM, self.alarmHandler) |
---|
[1749] | 311 | signal.alarm(3) |
---|
[1746] | 312 | try : |
---|
| 313 | answer = sock.recv(1024) |
---|
| 314 | except IOError, msg : |
---|
| 315 | break # our alarm handler was launched, probably |
---|
| 316 | else : |
---|
| 317 | readnext = 0 |
---|
| 318 | for line in [l.strip() for l in answer.split()] : |
---|
| 319 | if line.startswith("CODE=") : |
---|
| 320 | self.printerStatus = line.split("=")[1] |
---|
| 321 | elif line.startswith("PAGECOUNT") : |
---|
| 322 | readnext = 1 # page counter is on next line |
---|
| 323 | elif readnext : |
---|
| 324 | actualpagecount = int(line.strip()) |
---|
| 325 | readnext = 0 |
---|
| 326 | signal.alarm(0) |
---|
| 327 | self.printerInternalPageCounter = max(actualpagecount, self.printerInternalPageCounter) |
---|
| 328 | sock.close() |
---|
| 329 | |
---|
| 330 | def waitPrinting(self) : |
---|
| 331 | """Waits for printer status being 'printing'.""" |
---|
| 332 | while 1: |
---|
| 333 | self.retrievePJLValues() |
---|
[2027] | 334 | if self.printerStatus in ('10023',) : |
---|
[1746] | 335 | break |
---|
[2027] | 336 | self.parent.filter.logdebug(_("Waiting for printer %s to be printing...") % self.parent.filter.printername) |
---|
[1746] | 337 | time.sleep(ITERATIONDELAY) |
---|
| 338 | |
---|
| 339 | def waitIdle(self) : |
---|
| 340 | """Waits for printer status being 'idle'.""" |
---|
| 341 | idle_num = idle_flag = 0 |
---|
| 342 | while 1 : |
---|
| 343 | self.retrievePJLValues() |
---|
| 344 | idle_flag = 0 |
---|
[1933] | 345 | if self.printerStatus in ('10000', '10001', '35078') : |
---|
[1746] | 346 | idle_flag = 1 |
---|
| 347 | if idle_flag : |
---|
| 348 | idle_num += 1 |
---|
| 349 | if idle_num > STABILIZATIONDELAY : |
---|
| 350 | # printer status is stable, we can exit |
---|
| 351 | break |
---|
| 352 | else : |
---|
| 353 | idle_num = 0 |
---|
| 354 | self.parent.filter.logdebug(_("Waiting for printer %s's idle status to stabilize...") % self.parent.filter.printername) |
---|
| 355 | time.sleep(ITERATIONDELAY) |
---|
[1729] | 356 | |
---|
[1475] | 357 | class Accounter(AccounterBase) : |
---|
| 358 | def __init__(self, kotabackend, arguments) : |
---|
| 359 | """Initializes querying accounter.""" |
---|
| 360 | AccounterBase.__init__(self, kotabackend, arguments) |
---|
[1600] | 361 | self.isSoftware = 0 |
---|
[1475] | 362 | |
---|
| 363 | def getPrinterInternalPageCounter(self) : |
---|
| 364 | """Returns the printer's internal page counter.""" |
---|
[1739] | 365 | self.filter.logdebug("Reading printer %s's internal page counter..." % self.filter.printername) |
---|
[1685] | 366 | counter = self.askPrinterPageCounter(self.filter.printerhostname) |
---|
[1739] | 367 | self.filter.logdebug("Printer %s's internal page counter value is : %s" % (self.filter.printername, str(counter))) |
---|
[1475] | 368 | return counter |
---|
| 369 | |
---|
[1624] | 370 | def beginJob(self, printer) : |
---|
[1475] | 371 | """Saves printer internal page counter at start of job.""" |
---|
| 372 | # save page counter before job |
---|
[1624] | 373 | self.LastPageCounter = self.getPrinterInternalPageCounter() |
---|
| 374 | self.fakeBeginJob() |
---|
[1475] | 375 | |
---|
[1624] | 376 | def fakeBeginJob(self) : |
---|
| 377 | """Fakes a begining of a job.""" |
---|
| 378 | self.counterbefore = self.getLastPageCounter() |
---|
| 379 | |
---|
| 380 | def endJob(self, printer) : |
---|
[1475] | 381 | """Saves printer internal page counter at end of job.""" |
---|
| 382 | # save page counter after job |
---|
| 383 | self.LastPageCounter = self.counterafter = self.getPrinterInternalPageCounter() |
---|
| 384 | |
---|
[1713] | 385 | def getJobSize(self, printer) : |
---|
[1475] | 386 | """Returns the actual job size.""" |
---|
[1713] | 387 | if (not self.counterbefore) or (not self.counterafter) : |
---|
| 388 | # there was a problem retrieving page counter |
---|
| 389 | self.filter.printInfo(_("A problem occured while reading printer %s's internal page counter.") % printer.Name, "warn") |
---|
| 390 | if printer.LastJob.Exists : |
---|
| 391 | # if there's a previous job, use the last value from database |
---|
| 392 | self.filter.printInfo(_("Retrieving printer %s's page counter from database instead.") % printer.Name, "warn") |
---|
| 393 | if not self.counterbefore : |
---|
| 394 | self.counterbefore = printer.LastJob.PrinterPageCounter or 0 |
---|
| 395 | if not self.counterafter : |
---|
| 396 | self.counterafter = printer.LastJob.PrinterPageCounter or 0 |
---|
| 397 | before = min(self.counterbefore, self.counterafter) |
---|
| 398 | after = max(self.counterbefore, self.counterafter) |
---|
| 399 | self.counterbefore = before |
---|
| 400 | self.counterafter = after |
---|
[1734] | 401 | if (not self.counterbefore) or (not self.counterafter) or (self.counterbefore == self.counterafter) : |
---|
[1713] | 402 | self.filter.printInfo(_("Couldn't retrieve printer %s's internal page counter either before or after printing.") % printer.Name, "warn") |
---|
| 403 | self.filter.printInfo(_("Job's size forced to 1 page for printer %s.") % printer.Name, "warn") |
---|
[1714] | 404 | self.counterbefore = 0 |
---|
| 405 | self.counterafter = 1 |
---|
[1713] | 406 | else : |
---|
| 407 | self.filter.printInfo(_("No previous job in database for printer %s.") % printer.Name, "warn") |
---|
| 408 | self.filter.printInfo(_("Job's size forced to 1 page for printer %s.") % printer.Name, "warn") |
---|
| 409 | self.counterbefore = 0 |
---|
| 410 | self.counterafter = 1 |
---|
| 411 | |
---|
| 412 | jobsize = (self.counterafter - self.counterbefore) |
---|
| 413 | if jobsize < 0 : |
---|
| 414 | # Try to take care of HP printers |
---|
| 415 | # Their internal page counter is saved to NVRAM |
---|
| 416 | # only every 10 pages. If the printer was switched |
---|
| 417 | # off then back on during the job, and that the |
---|
| 418 | # counters difference is negative, we know |
---|
| 419 | # the formula (we can't know if more than eleven |
---|
| 420 | # pages were printed though) : |
---|
| 421 | if jobsize > -10 : |
---|
| 422 | jobsize += 10 |
---|
| 423 | else : |
---|
| 424 | # here we may have got a printer being replaced |
---|
| 425 | # DURING the job. This is HIGHLY improbable ! |
---|
| 426 | self.filter.printInfo(_("Inconsistent values for printer %s's internal page counter.") % printer.Name, "warn") |
---|
| 427 | self.filter.printInfo(_("Job's size forced to 1 page for printer %s.") % printer.Name, "warn") |
---|
| 428 | jobsize = 1 |
---|
[1475] | 429 | return jobsize |
---|
| 430 | |
---|
[1483] | 431 | def askPrinterPageCounter(self, printer) : |
---|
| 432 | """Returns the page counter from the printer via an external command. |
---|
| 433 | |
---|
| 434 | The external command must report the life time page number of the printer on stdout. |
---|
| 435 | """ |
---|
| 436 | commandline = self.arguments.strip() % locals() |
---|
[1746] | 437 | cmdlower = commandline.lower() |
---|
| 438 | if cmdlower == "snmp" : |
---|
[1729] | 439 | if hasSNMP : |
---|
| 440 | return self.askWithSNMP(printer) |
---|
| 441 | else : |
---|
| 442 | raise PyKotaAccounterError, _("Internal SNMP accounting asked, but Python-SNMP is not available. Please download it from http://pysnmp.sourceforge.net") |
---|
[1746] | 443 | elif cmdlower == "pjl" : |
---|
| 444 | return self.askWithPJL(printer) |
---|
[1729] | 445 | |
---|
[1483] | 446 | if printer is None : |
---|
| 447 | raise PyKotaAccounterError, _("Unknown printer address in HARDWARE(%s) for printer %s") % (commandline, self.filter.printername) |
---|
[1739] | 448 | while 1 : |
---|
| 449 | self.filter.printInfo(_("Launching HARDWARE(%s)...") % commandline) |
---|
| 450 | pagecounter = None |
---|
| 451 | child = popen2.Popen4(commandline) |
---|
[1483] | 452 | try : |
---|
[1739] | 453 | answer = child.fromchild.read() |
---|
| 454 | except IOError : |
---|
| 455 | # we were interrupted by a signal, certainely a SIGTERM |
---|
| 456 | # caused by the user cancelling the current job |
---|
[1680] | 457 | try : |
---|
[1739] | 458 | os.kill(child.pid, signal.SIGTERM) |
---|
| 459 | except : |
---|
| 460 | pass # already killed ? |
---|
| 461 | self.filter.printInfo(_("SIGTERM was sent to hardware accounter %s (pid: %s)") % (commandline, child.pid)) |
---|
| 462 | else : |
---|
| 463 | lines = [l.strip() for l in answer.split("\n")] |
---|
| 464 | for i in range(len(lines)) : |
---|
| 465 | try : |
---|
| 466 | pagecounter = int(lines[i]) |
---|
| 467 | except (AttributeError, ValueError) : |
---|
| 468 | self.filter.printInfo(_("Line [%s] skipped in accounter's output. Trying again...") % lines[i]) |
---|
| 469 | else : |
---|
| 470 | break |
---|
| 471 | child.fromchild.close() |
---|
| 472 | child.tochild.close() |
---|
| 473 | try : |
---|
| 474 | status = child.wait() |
---|
| 475 | except OSError, msg : |
---|
| 476 | self.filter.logdebug("Error while waiting for hardware accounter pid %s : %s" % (child.pid, msg)) |
---|
| 477 | else : |
---|
| 478 | if os.WIFEXITED(status) : |
---|
| 479 | status = os.WEXITSTATUS(status) |
---|
| 480 | self.filter.printInfo(_("Hardware accounter %s exit code is %s") % (self.arguments, str(status))) |
---|
| 481 | |
---|
| 482 | if pagecounter is None : |
---|
| 483 | message = _("Unable to query printer %s via HARDWARE(%s)") % (printer, commandline) |
---|
| 484 | if self.onerror == "CONTINUE" : |
---|
| 485 | self.filter.printInfo(message, "error") |
---|
| 486 | else : |
---|
| 487 | raise PyKotaAccounterError, message |
---|
| 488 | else : |
---|
| 489 | return pagecounter |
---|
[1729] | 490 | |
---|
| 491 | def askWithSNMP(self, printer) : |
---|
| 492 | """Returns the page counter from the printer via internal SNMP handling.""" |
---|
| 493 | acc = SNMPAccounter(self, printer) |
---|
| 494 | try : |
---|
| 495 | if (os.environ.get("PYKOTASTATUS") != "CANCELLED") and \ |
---|
| 496 | (os.environ.get("PYKOTAACTION") != "DENY") and \ |
---|
[2027] | 497 | (os.environ.get("PYKOTAPHASE") == "AFTER") and \ |
---|
| 498 | self.filter.jobSizeBytes : |
---|
[1729] | 499 | acc.waitPrinting() |
---|
| 500 | acc.waitIdle() |
---|
| 501 | except : |
---|
| 502 | if acc.printerInternalPageCounter is None : |
---|
| 503 | raise |
---|
| 504 | else : |
---|
[1739] | 505 | self.filter.printInfo(_("SNMP querying stage interrupted. Using latest value seen for internal page counter (%s) on printer %s.") % (acc.printerInternalPageCounter, self.filter.printername), "warn") |
---|
[1729] | 506 | return acc.printerInternalPageCounter |
---|
[1746] | 507 | |
---|
| 508 | def askWithPJL(self, printer) : |
---|
| 509 | """Returns the page counter from the printer via internal PJL handling.""" |
---|
| 510 | acc = PJLAccounter(self, printer) |
---|
| 511 | try : |
---|
| 512 | if (os.environ.get("PYKOTASTATUS") != "CANCELLED") and \ |
---|
| 513 | (os.environ.get("PYKOTAACTION") != "DENY") and \ |
---|
[2027] | 514 | (os.environ.get("PYKOTAPHASE") == "AFTER") and \ |
---|
| 515 | self.filter.jobSizeBytes : |
---|
[1746] | 516 | acc.waitPrinting() |
---|
| 517 | acc.waitIdle() |
---|
| 518 | except : |
---|
| 519 | if acc.printerInternalPageCounter is None : |
---|
| 520 | raise |
---|
| 521 | else : |
---|
| 522 | self.filter.printInfo(_("PJL querying stage interrupted. Using latest value seen for internal page counter (%s) on printer %s.") % (acc.printerInternalPageCounter, self.filter.printername), "warn") |
---|
| 523 | return acc.printerInternalPageCounter |
---|