[1475] | 1 | # PyKota |
---|
| 2 | # -*- coding: ISO-8859-15 -*- |
---|
| 3 | # |
---|
| 4 | # PyKota - Print Quotas for CUPS and LPRng |
---|
| 5 | # |
---|
| 6 | # (c) 2003-2004 Jerome Alet <alet@librelogiciel.com> |
---|
| 7 | # This program is free software; you can redistribute it and/or modify |
---|
| 8 | # it under the terms of the GNU General Public License as published by |
---|
| 9 | # the Free Software Foundation; either version 2 of the License, or |
---|
| 10 | # (at your option) any later version. |
---|
| 11 | # |
---|
| 12 | # This program is distributed in the hope that it will be useful, |
---|
| 13 | # but WITHOUT ANY WARRANTY; without even the implied warranty of |
---|
| 14 | # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the |
---|
| 15 | # GNU General Public License for more details. |
---|
| 16 | # |
---|
| 17 | # You should have received a copy of the GNU General Public License |
---|
| 18 | # along with this program; if not, write to the Free Software |
---|
| 19 | # Foundation, Inc., 59 Temple Place, Suite 330, Boston, MA 02111-1307, USA. |
---|
| 20 | # |
---|
| 21 | # $Id$ |
---|
| 22 | # |
---|
| 23 | # $Log$ |
---|
[1494] | 24 | # Revision 1.3 2004/05/24 14:36:40 jalet |
---|
| 25 | # Revert to old polling loop. Will need optimisations |
---|
| 26 | # |
---|
[1483] | 27 | # Revision 1.2 2004/05/18 14:49:22 jalet |
---|
| 28 | # Big code changes to completely remove the need for "requester" directives, |
---|
| 29 | # jsut use "hardware(... your previous requester directive's content ...)" |
---|
| 30 | # |
---|
[1475] | 31 | # Revision 1.1 2004/05/13 13:59:30 jalet |
---|
| 32 | # Code simplifications |
---|
| 33 | # |
---|
| 34 | # |
---|
| 35 | # |
---|
| 36 | |
---|
| 37 | import sys |
---|
| 38 | import os |
---|
[1483] | 39 | import popen2 |
---|
[1475] | 40 | from pykota.accounter import AccounterBase, PyKotaAccounterError |
---|
| 41 | |
---|
| 42 | class Accounter(AccounterBase) : |
---|
| 43 | def __init__(self, kotabackend, arguments) : |
---|
| 44 | """Initializes querying accounter.""" |
---|
| 45 | AccounterBase.__init__(self, kotabackend, arguments) |
---|
| 46 | self.isDelayed = 1 # With the pykota filter, accounting is delayed by one job |
---|
| 47 | |
---|
| 48 | def getPrinterInternalPageCounter(self) : |
---|
| 49 | """Returns the printer's internal page counter.""" |
---|
| 50 | self.filter.logdebug("Reading printer's internal page counter...") |
---|
| 51 | try : |
---|
[1483] | 52 | counter = self.askPrinterPageCounter(self.filter.printerhostname) |
---|
| 53 | except PyKotaAccounterError, msg : |
---|
[1475] | 54 | # can't get actual page counter, assume printer is off or warming up |
---|
| 55 | # log the message anyway. |
---|
| 56 | self.filter.logger.log_message("%s" % msg, "warn") |
---|
| 57 | counter = None |
---|
| 58 | self.filter.logdebug("Printer's internal page counter value is : %s" % str(counter)) |
---|
| 59 | return counter |
---|
| 60 | |
---|
| 61 | def beginJob(self, userpquota) : |
---|
| 62 | """Saves printer internal page counter at start of job.""" |
---|
| 63 | # save page counter before job |
---|
| 64 | self.LastPageCounter = self.counterbefore = self.getPrinterInternalPageCounter() |
---|
| 65 | |
---|
| 66 | def endJob(self, userpquota) : |
---|
| 67 | """Saves printer internal page counter at end of job.""" |
---|
| 68 | # save page counter after job |
---|
| 69 | self.LastPageCounter = self.counterafter = self.getPrinterInternalPageCounter() |
---|
| 70 | |
---|
| 71 | def getJobSize(self) : |
---|
| 72 | """Returns the actual job size.""" |
---|
| 73 | try : |
---|
| 74 | jobsize = (self.counterafter - self.counterbefore) |
---|
| 75 | if jobsize < 0 : |
---|
| 76 | # Try to take care of HP printers |
---|
| 77 | # Their internal page counter is saved to NVRAM |
---|
| 78 | # only every 10 pages. If the printer was switched |
---|
| 79 | # off then back on during the job, and that the |
---|
| 80 | # counters difference is negative, we know |
---|
| 81 | # the formula (we can't know if more than eleven |
---|
| 82 | # pages were printed though) : |
---|
| 83 | if jobsize > -10 : |
---|
| 84 | jobsize += 10 |
---|
| 85 | else : |
---|
| 86 | # here we may have got a printer being replaced |
---|
| 87 | # DURING the job. This is HIGHLY improbable ! |
---|
| 88 | jobsize = 0 |
---|
| 89 | except : |
---|
| 90 | # takes care of the case where one counter (or both) was never set. |
---|
| 91 | jobsize = 0 |
---|
| 92 | return jobsize |
---|
| 93 | |
---|
| 94 | def doAccounting(self, userpquota) : |
---|
| 95 | """Does print accounting and returns if the job status is ALLOW or DENY.""" |
---|
| 96 | # Get the page counter directly from the printer itself |
---|
| 97 | counterbeforejob = self.getPrinterInternalPageCounter() or 0 |
---|
| 98 | |
---|
| 99 | # Is the current user allowed to print at all ? |
---|
| 100 | action = self.filter.warnUserPQuota(userpquota) |
---|
| 101 | |
---|
| 102 | # adds the current job to history |
---|
| 103 | userpquota.Printer.addJobToHistory(self.filter.jobid, userpquota.User, counterbeforejob, action, filename=self.filter.preserveinputfile, title=self.filter.title, copies=self.filter.copies, options=self.filter.options) |
---|
| 104 | return action |
---|
[1483] | 105 | |
---|
| 106 | def askPrinterPageCounter(self, printer) : |
---|
| 107 | """Returns the page counter from the printer via an external command. |
---|
| 108 | |
---|
| 109 | The external command must report the life time page number of the printer on stdout. |
---|
| 110 | """ |
---|
| 111 | commandline = self.arguments.strip() % locals() |
---|
| 112 | if printer is None : |
---|
| 113 | raise PyKotaAccounterError, _("Unknown printer address in HARDWARE(%s) for printer %s") % (commandline, self.filter.printername) |
---|
| 114 | error = 1 |
---|
| 115 | pagecounter = None |
---|
| 116 | child = popen2.Popen4(commandline) |
---|
| 117 | try : |
---|
| 118 | pagecounter = int(child.fromchild.readline().strip()) |
---|
| 119 | except ValueError : |
---|
| 120 | pass |
---|
| 121 | except IOError : |
---|
| 122 | # we were interrupted by a signal, certainely a SIGTERM |
---|
| 123 | # caused by the user cancelling the current job |
---|
| 124 | try : |
---|
| 125 | os.kill(child.pid, signal.SIGTERM) |
---|
| 126 | except : |
---|
| 127 | pass # already killed ? |
---|
| 128 | self.filter.logger.log_message(_("SIGTERM was sent to hardware accounter %s (pid: %s)") % (commandline, child.pid), "info") |
---|
| 129 | else : |
---|
| 130 | error = 0 |
---|
| 131 | child.fromchild.close() |
---|
| 132 | child.tochild.close() |
---|
[1494] | 133 | try : |
---|
| 134 | status = child.wait() |
---|
| 135 | except OSError, msg : |
---|
| 136 | self.filter.logdebug("Error while waiting for hardware accounter pid %s : %s" % (child.pid, msg)) |
---|
| 137 | error = 1 |
---|
[1483] | 138 | if (not error) and os.WIFEXITED(status) and (not os.WEXITSTATUS(status)) : |
---|
| 139 | return pagecounter |
---|
| 140 | else : |
---|
| 141 | raise PyKotaAccounterError, _("Unable to query printer %s via HARDWARE(%s)") % (printer, commandline) |
---|