root / pykota / trunk / conf / pykota.conf.sample @ 2407

Revision 2406, 37.2 kB (checked in by jerome, 19 years ago)

Added a note about the 'directory' directive's value on my own system

  • Property svn:eol-style set to native
  • Property svn:keywords set to Author Date Id Revision
Line 
1# PyKota sample configuration file
2#
3#
4# File format :
5#
6#   - A mandatory [global] section :
7#
8#     Contains configuration directives which apply for all printers.
9#     Some directives MUST be set in the [global] section, e.g.
10#     database related directives.
11#
12#   - Any number of optional [PrintQueueName] sections :
13#
14#     Contain directives which apply for a particular print queue only.
15#
16#     Override the values of the same directives present in [global].
17#
18#
19# Directives format :
20#
21#   - Directive's name, followed by ':' followed by the directive's value.
22#
23#   - No leading whitespace : leading whitespace tell the parser that the
24#     current directive is the continuation of the previous one. Use with
25#     care and only when you need it.
26#
27#
28# PyKota - Print Quotas for CUPS and LPRng
29#
30# (c) 2003, 2004, 2005 Jerome Alet <alet@librelogiciel.com>
31# This program is free software; you can redistribute it and/or modify
32# it under the terms of the GNU General Public License as published by
33# the Free Software Foundation; either version 2 of the License, or
34# (at your option) any later version.
35#
36# This program is distributed in the hope that it will be useful,
37# but WITHOUT ANY WARRANTY; without even the implied warranty of
38# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
39# GNU General Public License for more details.
40#
41# You should have received a copy of the GNU General Public License
42# along with this program; if not, write to the Free Software
43# Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA.
44#
45# $Id$
46#
47
48[global]
49# Storage backend for quotas
50# only PGStorage (PostgreSQL) and LDAPStorage (OpenLDAP) are supported.
51# MySQL and BerkeleyDB are planned.
52
53# the 'postgresql' value is deprecated, use 'pgstorage' instead.
54storagebackend: pgstorage
55
56# Quota Storage Server hostname (and optional port)
57# e.g. db.example.com:5432
58storageserver: localhost
59
60#
61# name of the Quota Storage Database
62storagename: pykota
63
64#
65# Quota Storage normal user's name and password
66# These two fields contain a username and optional password
67# which may give readonly access to your print quota database.
68#
69# PLEASE ENSURE THAT THIS USER CAN'T WRITE TO YOUR PRINT QUOTA
70# DATABASE, OTHERWISE ANY USER WHO COULD READ THIS CONFIGURATION
71# FILE COULD CHANGE HIS PRINT QUOTA.
72#
73storageuser: pykotauser
74# storageuserpw: Comment out if unused, or set to Quota Storage user password
75
76# Should the database caching mechanism be enabled or not ?
77# If unset, caching is disabled. Possible values Y/N/YES/NO
78# caching mechanism works with both PostgreSQL and OpenLDAP backends
79# but may be really interesting only with OpenLDAP.
80#
81# ACTIVATING CACHE MAY CAUSE PRECISION PROBLEMS IN PRINT ACCOUNTING
82# IF AN USER PRINTS ON SEVERAL PRINTERS AT THE SAME TIME.
83# YOU MAY FIND IT INTERESTING ANYWAY, ESPECIALLY FOR LDAP.
84#
85# FYI, I ALWAYS SET IT TO YES !
86#
87storagecaching: No
88
89# Should full job history be disabled ?
90# If unset or set to No, full job history is kept in the database.
91# This will be useful in the future when the report generator
92# will be written.
93# Disabling the job history can be useful with heavily loaded
94# LDAP servers, to not make the LDAP tree grow out of control.
95# Disabling the job history with the PostgreSQL backend works too
96# but it's probably less useful than with LDAP.
97disablehistory: No
98
99# LDAP example, uncomment and adapt it to your own configuration :
100#storagebackend: ldapstorage
101#storageserver: ldap://ldap.example.com:389
102#storagename: dc=example,dc=com
103#storageuser: cn=notadmin,dc=example,dc=com
104#storageuserpw: abc.123
105#
106# TLS support for LDAP
107#
108# ldaptls can be set to either Yes or No
109# the default value when not set is No, meaning that TLS won't be used.
110#ldaptls: No
111#
112# cacert points to the CA Certificate file to use for TLS.
113# Ensure that every user who can launch PyKota commands can read this file.
114# There's NO default value for this directive.
115#cacert /etc/pykota/mycertfile
116#
117#
118# Here we define some helpers to know where
119# to plug into an existing LDAP directory
120#userbase: ou=People,dc=example,dc=com
121#userrdn: uid
122#balancebase: ou=People,dc=example,dc=com
123#balancerdn: uid
124#groupbase: ou=Groups,dc=example,dc=com
125#grouprdn: cn
126#printerbase: ou=Printers,ou=PyKota,dc=example,dc=com
127#printerrdn: cn
128#jobbase: ou=Jobs,ou=PyKota,dc=example,dc=com
129#lastjobbase: ou=LastJobs,ou=PyKota,dc=example,dc=com
130#billingcodebase: ou=BillingCodes,ou=PyKota,dc=example,dc=com
131
132# These two fields are special, they either accept a branch
133# dn, like an ou for example, or the special keywords 'user'
134# and 'group'. If 'user' or 'group' is used, the print quota
135# entries will be created below the user or group entry itself,
136# which will then be used like a branch (you can mix and match
137# different values depending on what you want to do).
138#userquotabase: user
139#userquotabase: ou=UQuotas,ou=PyKota,dc=example,dc=com
140#groupquotabase: group
141#groupquotabase: ou=GQuotas,ou=PyKota,dc=example,dc=com
142
143#
144# How to create new accounts and groups
145# authorized values are "below" and "attach(objectclass name [, fail|warn])"
146#
147# "below" creates the new accounts/groups as standalone entries
148# below the above defined 'userbase' ou
149#
150# attach(objectclass name [, action]) tries to find some existing user/group
151# using the above defined 'userrdn' or 'grouprdn' and 'userbase'
152# 'groupbase', and attach the PyKota specific entries to it.
153# if action is "warn" and no entry exists to attach to, a new
154# entry is created, and a message is logged.
155# if action is "fail" and no entry exists to attach to, program
156# logs an error message and aborts.
157# if action is not set, the default value is "fail".
158#
159# a possible value:  newuser: attach(posixAccount, warn)
160#newuser : below
161#newgroup : below
162#
163# LDAP attribute which stores the user's email address
164#usermail : mail
165
166#
167# Choose what attribute contains the list of group members
168# common values are : memberUid, uniqueMember, member
169#groupmembers: memberUid
170
171# Activate low-level LDAP cache yes/no
172# Nothing to do with "storagecaching" which is higher level
173# and database independant.
174# This saves some search queries and may help with heavily
175# loaded LDAP servers.
176# This is EXPERIMENTAL.
177#
178# BEWARE : SETTING THIS TO 'YES' CAUSES PROBLEMS FOR NOW
179# BETTER TO LET IT SET TO 'NO'
180# ldapcache: no
181
182# Where to log ?
183# supported values : stderr, system (system means syslog, but don't use 'syslog' here)
184# if the value is not set then the default SYSTEM applies.
185logger: system
186
187# Enable debugging ? Put YES or NO there.
188# debug is set to yes in this sample
189# configuration file, so debugging is activated
190# when configuring PyKota. After all works, just
191# put NO instead to save some disk space in your
192# logs.
193debug : Yes
194
195#
196# The URL to PyKota's logo when used from the CGI scripts.
197# You can use your own logo by modifying the URL below.
198# If not defined, the default URL is the same as the
199# one defined below
200logourl : http://www.librelogiciel.com/software/PyKota/pykota.png
201
202#
203# The destination to which the web browser will be redirected
204# when you click on the logo defined above.
205# If not defined, the default URL is the same as the
206# one defined below
207logolink : http://www.librelogiciel.com/software/
208
209#
210# Mail server to use to warn users
211# If the value is not set then localhost is used.
212smtpserver: localhost
213
214# Crash messages' recipient : in addition to the log files
215# each software crash can be sent to the author of PyKota
216# or any other person of your choice. By default this
217# is disabled. The recipient pykotacrashed@librelogiciel.com
218# reaches PyKota's author.
219# The 'adminmail' (defined a bit below) is CCed.
220#
221# Privacy concerns : what is sent is only :
222#
223#        - a copy of the software's traceback
224#        - a copy of the software's command line arguments
225#        - a copy of the software's environment variables
226#
227# suggested value
228# crashrecipient: pykotacrashed@librelogiciel.com
229
230# Email domain
231# If the value is not set, and the mail attribute for the user
232# is not set in the PyKota storage, be it LDAP (see usermail directive
233# above) or PostgreSQL, then email messages are sent to
234# username@smtpserver
235#
236# If the value is set, then email messages are sent to
237# username@maildomain using the SMTP server defined above
238#
239# Set the appropriate value below, example.com set as per RFC2606.
240maildomain: example.com
241
242# Should we force usernames to be all lowercase when printing ?
243# Default is No.
244# This is a global option only.
245# Some people reported that WinXP sends mixed case usernames
246# setting 'utolower: Yes' solves the problem.
247# Of course you have to use lowercase only when adding
248# users with edpykota, because ALL database accesses are
249# still case sensitive.
250#
251# If utolower is Yes, the usernames received from the printing
252# system is converted to lowercase at the start of the cupspykota
253# backend or of the lprngpykota filter.
254#
255# If utolower is No, which is the default, strict case checking
256# is done, this means that users 'Jerome' and 'jerome' are
257# different. Printer and groups names are ALWAYS case sensitive.
258utolower: No
259
260# Should we split usernames on a specific separator when printing ?
261# Default is No, i.e. if the value is unset.
262# This is a global option only.
263# This option adds support for Samba's Winbind utility, which
264# prefixes usernames with domain name and separator character.
265# Of course if you set this then you have to use NO separator when
266# adding users with edpykota.
267#
268# If winbind_separator is set, the usernames received from the printing
269# system are split on the separator's value, and only the last part
270# (real username) is used.
271#
272# If winbind_separator is not set, which is the default, strict
273# username equality checking will be done (modulo the setting
274# of the 'utolower' directive), this means that users 'DOMAIN1/jerome',
275# 'Domain2/jerome' and 'jerome' are different.
276# winbind_separator: /
277
278# When creating users or groups accounts, should we reject users
279# or groups which are unknown from the system ?
280# The default if unset is NO. This means that by default, you
281# can create users or groups for which `getent passwd username`
282# or `getent group groupname` returns nothing.
283#
284# Allowed values : Yes | No
285# Default value : No
286#
287# reject_unknown: No
288
289# Do we want to hide jobs' title, filename and options for privacy
290# reasons ?
291# This may be required in some countries (Italy comes to mind).
292# Allowed values are YES and NO.
293# If unset, the default value is NO, meaning that jobs' title, filename
294# and options will be saved into the history.
295# This option can't be set on a per printer basis, only into the
296# [global] section.
297privacy : no
298
299# Should we strip off some characters from the beginning of
300# print jobs' titles ? This can be used to remove smbprn.??????
301# which sometimes appear when printing in raw mode from Windows
302# through Samba.
303# This setting only applies at printing time.
304# When not set, titles are used as received from the printing system.
305# The default is to not strip any character off of jobs' titles.
306# This value can be set either globally or on a per printer basis
307# If both are defined, the printer option has priority.
308# striptitle : smbprn.??????
309
310# Should we launch a command to overwrite the job's ticket ?
311# This allows a command to overwrite the username and/or the
312# billing code used, or to deny the job.
313# If unset no command is launched and the job's username and
314# billing code are used as they are received.
315# To overwrite the job's ticket, the command has to print
316# on its standard output one or more of the following lines,
317# without any prefix or space character :
318#
319#    USERNAME=the_username_we_want_to_overwrite_with
320#    BILLINGCODE=the_billingcode_we_want_to_overwrite_with
321#    DENY
322#
323# NB : the output is entirely read, and the latest value
324# seen is used, so you command can output several usernames
325# or billing codes and only the latest ones will be used.
326# If only USERNAME= lines are printed, the billing code,
327# if any, is used unchanged.
328# If only BILLINGCODE= lines are printed, the username is
329# used unchanged.
330# If DENY is output, but is followed by new USERNAME= or
331# BILLINGCODE= lines, the job is not denied.
332#
333# This value can be set either globally or on a per printer basis
334# If both are defined, the printer option has priority.
335#
336# overwrite_jobticket : /path/to/some/script/or/command
337
338# What should we do when we print and the billing code used is
339# not present in the database ?
340# The default value is 'create' which adds the billing code to the
341# database.
342# Other values can be :
343#       deny
344#     which silently rejects the job.
345# or :
346#       deny(your script here)
347#     if you put the path to a script or command here, it is executed, for
348#     example you can open a popup window explaining why the job was
349#     rejected.
350#
351# This value can be set either globally or on a per printer basis
352# If both are defined, the printer option has priority.
353#
354# unknown_billingcode : create
355
356# Where should we store our (temporary) files when printing ?
357# if unset, defaults to a system directory dedicated to temporary
358# files and evaluated at runtime (see Python's documentation
359# for the tempfile.gettempdir() function).
360# This value can be set either globally or on a per printer basis
361# If both are defined, the printer option has priority.
362# On my system, when not set, the /var/spool/cups/tmp directory is used.
363# directory : /tmp
364# directory : /var/spool/cups
365
366# Should we keep our work files on disk after printing ?
367# If unset, temporary files are deleted once the work is finished.
368# If set to yes, files are kept on disk in the 'directory'
369# named with the previous directive.
370# This value can be set either globally or on a per printer basis
371# If both are defined, the printer option has priority.
372# Default value is No, meaning temporary files are deleted
373# keepfiles : yes
374keepfiles : no
375
376
377# What is the accounting backend to use
378#
379# supported values :
380#
381#    - hardware : asks the printer for its lifetime page counter
382#                 via either SNMP, AppleTalk, or any external
383#                 command. This method is the recommended one
384#                 in PyKota since its beginning.
385#
386#                 In the lines below "%(printer)s" is automatically replaced
387#                 at run time with your printer's Fully Qualified Domain Name
388#                 for network printers, if PyKota can extract it from its
389#                 environment.
390#                 e.g. myprinter.example.com
391#
392#         Recommended values :
393#
394#             accounter: hardware(snmp)
395#
396#               Extracts the printer's internal page counter via SNMP.
397#
398#         Or :
399#
400#             accounter: hardware(pjl)
401#
402#               Extracts the printer's internal page counter via PJL queries over port tcp/9100.
403#
404#         Other Examples :
405#         
406#             accounter: hardware(/usr/bin/snmpget -v1 -c public -Ov %(printer)s mib-2.43.10.2.1.4.1.1 | cut -f 2,2 -d " ")
407#         
408#         Another untested example, using npadmin :
409#         
410#             accounter: hardware(/usr/bin/npadmin --pagecount %(printer)s)
411#         
412#         Another example, for AppleTalk printers which works fine :
413#         (You may need the pap CUPS backend installed, and copy the
414#         pagecount.ps file from untested/netatalk into /etc or any
415#         appropriate location)
416#         
417#             accounter: hardware(/usr/share/pykota/papwaitprinter.sh "MyPrinter:LaserWriter@*" && /usr/bin/pap -p "MyPrinter:LaserWriter@*" /usr/share/pykota/pagecount.ps  2>/dev/null | /bin/grep -v status | /bin/grep -v Connect | /usr/bin/tail -1)
418#         
419#         An example for parallel printers like the HP Laserjet 5MP :
420#         
421#             accounter: hardware(/bin/cat /usr/share/pykota/pagecount.pjl >/dev/lp0 && /usr/bin/head -2 </dev/lp0 | /usr/bin/tail -1)
422#         
423#         This value can be set either globally or per printer or both.
424#         If both are defined, the printer option has priority.
425#         
426#         Some examples and comments provided by Bob Martel from csuohio.edu
427#         
428#         For several printers I could not get the page count using snmpget.  I
429#         resorted to snmpwalk:
430#         
431#             accounter: hardware(/opt/local/net-snmp/bin/snmpwalk -v 1 -Cc -c public %(printer)s | grep mib-2.43.10.2.1.4.1.1 | cut -d " " -f4)
432#         
433#         The last example is still more ugly, some of the printers only provided
434#         their counters without names, but at least always on the same line:
435#         
436#             accounter: hardware(/opt/local/net-snmp/bin/snmpwalk -v 1 -Cc -c public -Ov %(printer)s | grep Counter32 | tail -2 | head -1 | cut -d " " -f2)
437#         
438#         An example using netcat and a preformatted PJL job which you can find
439#         in the untested/pjl directory, which is sent to a JetDirect print
440#         server on port 9100 :
441#         
442#             accounter: hardware(/bin/nc -w 2 %(printer)s 9100 </usr/share/pykota/pagecount.pjl | /usr/bin/tail -2)
443#         
444#         An example using the contributed pagecount.pl script which does
445#         the same as above, but should work on more printers :
446#         
447#             accounter: hardware(LC_ALL=C /usr/share/pykota/pagecount.pl %(printer)s 9100)
448#         
449#         NB : the LC_ALL=C is used because sometimes Perl can correctly set locale and is verbose
450#              about it, causing PyKota to miss the correct answer.
451#
452#         WARNING : In any case, when using an hardware accounter, please test the command line outside
453#                   of PyKota before. This will save you some headaches in case it doesn't work as expected.
454#         
455#         The waitprinter.sh is there to wait until the printer is idle again.
456#         This should prevent a job to be sent to the printer while another one is
457#         not yet finished (not all pages are printed, but the complete job is in
458#         the printer)
459#         
460#   YOU ABSOLUTELY HAVE TO BE SURE YOU HAVE A SCRIPT WHICH WAITS FOR THE
461#   PRINTER BEING READY BEFORE ASKING FOR ITS INTERNAL PAGE COUNTER.
462#         
463#   PYKOTA INCLUDES SUCH SCRIPTS FOR SNMP AND APPLETALK PRINTERS, MORE TO COME
464#
465#   SOME OF THE ABOVE EXAMPLES DON'T USE SUCH A SCRIPT, YOU HAVE BEEN WARNED
466#
467#
468#   WITH THE SPECIAL MAGIC hardware(snmp) AND hardware(pjl) VALUES, PYKOTA
469#   TAKES CARE OF ALL THIS FOR YOU, SO PLEASE UNDERSTAND THAT IT IS PREFERABLE
470#   TO USE THESE TWO METHODS : THEY WORK FINE, REQUIRE LITTLE TO NO CPU,
471#   AND DO ALL THE HARD WORK AUTOMATICALLY. IF YOU REALLY NEED TO YOU CAN USE
472#   YOUR OWN EXTERNAL COMMANDS AS DESCRIBED ABOVE, JUST BE CAREFUL WITH THIS.
473#         
474#
475#    - software : delegates the job's size computation to any
476#                 external command of your choice.
477#
478#                 best choice for this is probably to set it
479#                 this way :
480#
481#                   accounter: software()
482#
483#                 which uses pkpgcounter's code internally to compute
484#                 the size of the job.
485#                 NB : YOU MUST NOW INSTALL pkpgcounter FOR PyKota TO WORK.
486#
487#                 You could obtain exactly the same result with :
488#
489#                   accounter: software(/usr/bin/pkpgcounter)
490#
491#                 But in this case the job would be passed through
492#                 pkpgcounter's parser a second time.
493#
494#                 pkpgcounter is a command line tool which was
495#                 part of PyKota and which can handle several types
496#                 of documents. It is now distributed separately.
497#
498#                 while pkpgcounter is the recommended value if you want
499#                 to use an external command here, you can use whatever
500#                 command you want provided your command accepts the job's
501#                 data on its standard input and prints the job's size in
502#                 pages as a single integer on its standard output.
503#
504# This value can be set either globally or on a per printer basis
505# If both are defined, the printer option has priority.
506#
507# accounter: hardware(/usr/share/pykota/waitprinter.sh %(printer)s && /usr/bin/snmpget -v1 -c public -Ov %(printer)s mib-2.43.10.2.1.4.1.1 | cut -f 2,2 -d " ")
508# accounter: hardware(snmp)
509# accounter: hardware(pjl)
510# accounter: software(/usr/bin/pkpgcounter)
511#
512# The following, software without any argument, works since PyKota 1.21
513# and uses pkpgcounter's code internally.
514accounter: software()
515
516# What should we do if the accounter's subprocess doesn't return
517# a valid result (for example doesn't return an integer on its stdout)
518#
519# Valid values are : 'continue' and 'stop'. 'stop' is the default
520# if unset.
521#
522# 'continue' means try to process as usual, this may introduce
523# accounting errors and free jobs. This was the default behavior
524# until v1.20alpha5.
525#
526# 'stop' means fail and stop the print queue. If an accounter
527# error occurs, most of the time this is a misconfiguration, so
528# stopping the print queue is usually the better thing to do
529# until the admin has fixed the configuration.
530#
531# This value can be set either globally or on a per printer basis
532# If both are defined, the printer option has priority.
533#
534# NB : This directive shouldn't do much now because in case
535# of external accounter error, PyKota just loops.
536#
537# onaccountererror: continue
538onaccountererror: stop
539
540# Print Quota administrator
541# These values can be set either globally or per printer or both.
542# If both are defined, the printer option has priority.
543# If these values are not set, the default admin root
544# and the default adminmail root@localhost are used.
545admin: John Doe
546adminmail: root@localhost
547
548#
549# Who should we send an email to in case a quota is reached ?
550# possible values are : DevNull, User, Admin, Both, External(some command)
551# The Both value means that the User and the Admin will receive
552# an email message.
553# The DevNull value means no email message will be sent.
554# This value can be set either globally or per printer or both.
555# If both are defined, the printer option has priority.
556# If the value is not set, then the default BOTH applies.
557#
558#   Format of the external syntax :
559#
560#       mailto: external(/usr/bin/mycommand >/dev/null)
561#
562#   You can use :
563#
564#       '%(action)s'            will contain either WARN or DENY
565#       '%(username)s'          will contain the user's name
566#       '%(printername)s'       will contain the printer's name
567#       '%(email)s'             will contain the user's email address
568#       '%(message)s'           will contain the message if you want
569#                               to use it.
570#
571#   On your command line, to pass arguments to your command.
572#   Example :
573#
574#       mailto: external(/usr/bin/callpager %(username)s "Quota problem on %(printername)s" >/dev/null)
575#
576#   To automatically send a WinPopup message (this may only work with a PDC,
577#   here the same machine does Samba as PDC + CUPS) :
578#
579#       mailto: external(echo "%(message)s"  | /usr/bin/iconv --to-code utf-8 --from-code iso-8859-15 | /usr/bin/smbclient -M "%(username)s" 2>&1 >/dev/null)
580#
581#   NB : I use ISO-8859-15, but Windows expects UTF-8, so we pipe the message
582#        into iconv before sending it to the Windows user.
583#
584# or more simply :
585#
586#       mailto: external(/usr/share/pykota/mailandpopup.sh %(username)s %(printername)s "%(email)s" "%(message)s" 2>&1 >/dev/null)
587#
588#   NB : The mailandpopup.sh shell script is now included in PyKota
589#
590#   NB : in ANY case, don't forget to redirect your command's standard output
591#        somewhere (e.g. >/dev/null) so that there's no perturbation to the
592#        underlying layer (filter or backend)
593#
594mailto: both
595
596#
597# Grace delay in days
598# This value can be set either globally or per printer or both.
599# If both are defined, the printer option has priority.
600# If the value is not set then the default seven (7) days applies.
601gracedelay: 7
602
603#
604# Poor man's threshold
605# If account balance reaches below this amount,
606# a warning message is sent by email
607#
608# If unset, default poor man's threshold is 1.0.
609# This option can only appear in the global section
610poorman: 2.0
611
612# Poor man's warning message
613# The warning message that is sent if the "poorman" value is reached
614# Again this must appear in the global section
615poorwarn: Your Print Quota account balance is low.
616 Soon you'll not be allowed to print anymore.
617
618# Soft limit reached warning message
619# The warning message that is sent if the soft quota limit is reached
620# May appear either globally or on a per-printer basis
621softwarn: Your Print Quota Soft Limit is reached.
622 This means that you may still be allowed to print for some
623 time, but you must contact your administrator to purchase
624 more print quota.
625 
626# Hard limit reached error message
627# The error message that is sent if the hard quota limit is reached
628# May appear either globally or on a per-printer basis
629hardwarn: Your Print Quota Hard Limit is reached.
630 This means that you are not allowed to print anymore.
631 Please contact your administrator at root@localhost
632 as soon as possible to solve the problem.
633
634# one section per printer, or no other section at all if all options
635# are defined globally.
636# Each section's name must be the same as the printer's queue name as defined
637# in your printing system, be it CUPS or LPRng, between square brackets, for
638# example a print queue named 'hpmarketing' would appear in this file as
639# [hpmarketing]
640
641
642# Default policy to apply when either :
643#
644#       - Printer doesn't exist in PyKota's database
645#       - User doesn't exist in PyKota's database
646#       - User has no quota entry for this Printer in PyKota's database
647#
648# Value can be either allow or deny or external(some command here)
649#
650# This value can be set either globally or per printer or both.
651# If both are defined, the printer option has priority.
652# If the value is not set then the default policy DENY applies.
653# There's no policy wrt inexistant groups, they are ignored.
654#
655# external policy can be used to launch any external command of your choice,
656# for example to automatically add the user to the quota storage
657# if he is unknown. Example :
658#
659#   policy: external(/usr/bin/edpykota --add --printer %(printername)s --softlimit 50 --hardlimit 60 %(username)s >/dev/null)
660#
661# NB : If you want to limit users by their account balance value, it is preferable to
662# use the following policy to automate user account creation on first print :
663#
664#   policy: external(/usr/bin/autopykota --initbalance 25.0 >/dev/null)
665#
666#   This will automatically add the user if he doesn't already exist, and
667#   set his initial balance value to 25.0 (for example). If the user already
668#   exists then his balance value will not be modified.
669#   Please don't use autopykota if you want to limit your users by page
670#   quota, and in any case, carefully read autopykota's help or manpage
671#   and understand its goal before using it in your own configuration.
672#
673# Of course you can launch any command of your choice with this, e.g. :
674#
675#   policy: external(/usr/local/bin/myadminscript.sh %(username)s >/dev/null)
676
677# You can use :
678#
679#       '%(username)s'          will contain the user's name
680#       '%(printername)s'       will contain the printer's name
681#
682#   On your command line, to pass arguments to your command.
683#
684#   NB : Don't forget to redirect your command's standard output somewhere
685#        (e.g. >/dev/null) so that there's no perturbation to the underlying
686#        layer (filter or backend)
687#
688# If the printer, user, or user quota entry still doesn't exist after
689# external policy command was launched (the external command didn't add it),
690# or if an error occured during the execution of the external policy
691# command, then the job is rejected.
692#
693policy: deny
694
695# Pre and Post Hooks
696# These directives allow the easy plug-in of any command of your choice
697# at different phases of PyKota's execution.
698# Pre and Post Hooks can access some of PyKota's internal information
699# by reading environment variables as described below.
700# The actual phase of PyKota's execution is available in the
701# PYKOTAPHASE environment variable.
702# Pre and Post Hooks can be defined either globally, per printer,
703# or both. If both are defined, the printer specific hook has
704# priority.
705#
706# List of available environment variables :
707# NB : Most of these variables are also available during the execution
708# of external commands defined in the accounter and mailto
709# directives.
710#
711# PYKOTADIRECTORY : The directory containing cupspykota's temporary files
712# PYKOTADATAFILE : The name of the temporary file which contains the
713#                  job's datas
714# PYKOTAINPUTFILE : The name of the file which contains the job's datas or
715#                   empty if datas come from stdin
716# PYKOTACONTROLFILE : The name of the IPP message file
717# PYKOTAMD5SUM : Contains an hexadecimal digest of the md5 sum of the job's datas
718# PYKOTAPHASE : BEFORE or AFTER the job is sent to the printer
719# PYKOTAACTION : ALLOW or DENY or WARN for current print job
720# PYKOTAUSERNAME : user's name
721# PYKOTAPRINTERNAME : printer's name
722# PYKOTAPGROUPS : list of printers groups the current printer is a member of
723# PYKOTAJOBID : job's id
724# PYKOTATITLE : job's title
725# PYKOTAFILENAME : job's filename
726# PYKOTACOPIES : number of copies
727# PYKOTAOPTIONS : job's options
728# PYKOTABALANCE : user's account balance
729# PYKOTALIFETIMEPAID : user's grand total paid
730# PYKOTALIMITBY : user print limiting factor, for example 'quota' or 'balance'
731# PYKOTAPAGECOUNTER : user's page counter on this printer
732# PYKOTALIFEPAGECOUNTER : user's life time page counter on this printer
733# PYKOTASOFTLIMIT : user's soft page limit on this printer
734# PYKOTAHARDLIMIT : user's hard page limit on this printer
735# PYKOTADATELIMIT : user's soft to hard limit date limit on this printer
736# PYKOTASTATUS : contains "CANCELLED" when SIGTERM was received by PyKota
737#                else is not set.
738# PYKOTAJOBSIZEBYTES : contains the job's size in bytes. Always available.
739# PYKOTAPRECOMPUTEDJOBSIZE : contains the precomputed job's size
740# PYKOTAPRECOMPUTEDJOBPRICE : contains the precomputed job's price
741# PYKOTAJOBORIGINATINGHOSTNAME : contains the client's hostname if
742#                                it is possible to retrieve it.
743# PYKOTAPRINTERHOSTNAME : the printer's hostname or IP address for network
744#                         printers, or "localhost" if not defined or not
745#                         meaningful.
746# PYKOTAWARNCOUNT : the number of times the user was forbidden to print but a banner
747#                   page was still printed on the current printer.                   
748# PYKOTAOVERCHARGE : user's overcharging factor.
749# PYKOTAJOBBILLING : Job's billing code if present (CUPS only)
750#
751
752# PreHook : gets executed after being sure the user, printer and user quota
753# entry on the printer both exist in the PyKota database, and after
754# checking if the user is allowed to print or not, but just before
755# the job is sent to the printer (if allowed)
756# prehook has access to many environment variables :
757#
758# PYKOTAACTION contains either "ALLOW", "WARN" or "DENY" and
759# represents the action which is to be done wrt the print job.
760# PYKOTAPHASE contains 'BEFORE' during execution of prehook
761#
762# uncomment the line below to see what environment variables are available
763# prehook: /usr/bin/printenv >/tmp/before
764
765# PostHook : gets executed after the job has been added to the history.
766# posthook has access to all the environment variables defined above,
767# as well as two additionnal environment variables : PYKOTAJOBPRICE
768# and PYKOTAJOBSIZE.
769# PYKOTAPHASE contains 'AFTER' during execution of posthook.
770#
771# uncomment the line below to see what environment variables are available
772# posthook: /usr/bin/printenv >/tmp/after
773
774# AccountBanner : how should banner accounting be done ?
775#
776# NB : CUPS ONLY FOR NOW !
777#
778# If enabled, banner pages printed from StartingBanner and/or EndingBanner
779# (depending on the value) will be included in the accounting for the
780# print job
781#
782# If disabled, banner pages printed from StartingBanner and EndingBanner will
783# *not* be included in the accounting for the print job
784#
785# IMPORTANT : CUPS generated banners are ALWAYS accounted for, although you
786#             can refund them by using negative prices on printers.
787#
788# Allowed values : Starting | Ending | None | Both
789#
790#       - Starting : only the starting banner will be accounted for.
791#       - Ending : only the ending banner will be accounted for.
792#       - Both : both starting and ending banners will be accounted for.
793#       - None : banners will not be accounted for.
794#
795# Default value :
796# accountbanner: Both
797
798# Maximal number of times the banner will still be printed if
799# the user is forbidden to print.
800#
801# NB : CUPS ONLY FOR NOW !
802#
803# This option can be set either globally or on a per printer basis.
804# Allowed values are 0 or any positive integer.
805# Default value is 0, which means that the banner won't be printed
806# at all if the user is forbidden to print.
807maxdenybanners: 0
808
809# StartingBanner : if defined will print a banner before the rest of the job
810# is printed. The argument can be a printable file, or an executable file.
811# If not executable, the file will be printed as is. If executable, the
812# file will be executed and its output will be printed.
813#
814# NB : CUPS ONLY FOR NOW !
815#
816# In any case, the banner content which will be sent to the printer
817# MUST be in a format your printer will accept !!!
818#
819# The pkbanner command included in PyKota can automatically generate
820# starting and ending banners in the PostScript format. You can use
821# this command in a pipe through GhostScript if your printer doesn't
822# accept PostScript as an input format.
823# NB : pkbanner's default page size is A4
824#
825# startingbanner: /home/joe/mystaticbanner.ps
826# startingbanner: /usr/bin/pkbanner --pagesize=A4 --logo="/home/joe/mylogo.jpeg" --url="http://tech.example.com"
827# startingbanner: /usr/bin/pkbanner | gs -q -dNOPAUSE -dBATCH -dPARANOIDSAFER -sOutputFile=- -sDEVICE=lj5mono -
828# startingbanner: /usr/bin/pkbanner
829
830# EndingBanner : if defined will print a banner after the job
831# has been printed. The argument can be a printable file, or an executable file.
832# If not executable, the file will be printed as is. If executable, the
833# file will be executed and its output will be printed.
834#
835# NB : CUPS ONLY FOR NOW !
836#
837# In any case, the banner content which will be sent to the printer
838# MUST be in a format your printer will accept !!!
839#
840# The pkbanner command included in PyKota can automatically generate
841# starting and ending banners in the PostScript format. You can use
842# this command in a pipe through GhostScript if your printer doesn't
843# accept PostScript as an input format.
844# NB : pkbanner's default page size is A4
845#
846# A static banner page
847# endingbanner: /home/joe/mystaticbanner.ps
848#
849# A banner with personnalized logo and url
850# endingbanner: /usr/bin/pkbanner --pagesize=A4 --logo="/home/joe/mylogo.jpeg" --url="http://tech.example.com"
851#
852# A banner in the format accepted by the printer
853# endingbanner: /usr/bin/pkbanner | gs -q -dNOPAUSE -dBATCH -dPARANOIDSAFER -sOutputFile=- -sDEVICE=lj5mono -
854#
855# A banner with more info on it, extracted from the yellow pages.
856# the string "Phone 111222333444" will be added to the banner page
857# if extractphone.sh returns 111222333444 for the current user.
858# endingbanner: /usr/bin/pkbanner Phone `extractphone.sh $PYKOTAUSERNAME`
859#
860# Default PyKota banner
861# endingbanner: /usr/bin/pkbanner
862
863# How should enforcement be done for this printer ?
864#
865# "laxist" is the default if value is not set, and allows users
866# to be over quota on their last job.
867#
868# "strict" tries to prevent users from ever being over quota.
869#
870# Enforcement can be defined either globally, per printer,
871# or both. If both are defined, the printer specific enforcement
872# setting has priority.
873#
874# valid values : "strict" or "laxist"
875#
876# default value
877# enforcement : laxist
878enforcement : strict
879
880# Should we trust the job size on this printer ?
881#
882# "trustjobsize : yes" is the default, the jobsize, either computed
883# by the hardware or by software is trusted.
884#
885# "trustjobsize : >N:precomputed" : uses the precomputed value if jobsize > N pages
886# "trustjobsize : >N:25" : uses 25 if jobsize is >N pages
887#
888# General form : ">n:m" where n is a positive integer, and m is
889# either the word 'precomputed' or a positive integer.
890# The special form "yes" is also accepted and is the default.
891#
892# This directive can be set either globally or on a per printer
893# basis. Use this directive when hardware accounting for a particular
894# printer produces some glitches due to the printer returning
895# incorrect answers.
896#
897# NB : DON'T MODIFY THIS IF YOU DON'T NEED TO. THIS IS ONLY TO BE USED
898# AS A WORKAROUND FOR SOME PRINTERS. IT'S PROBABLY BETTER TO ALWAYS
899# SET THIS DIRECTIVE TO 'yes'. THIS DIRECTIVE WILL ONLY BE HONORED
900# IF PYKOTA DETECTS A DIFFERENCE BETWEEN THE PRECOMPUTED JOB SIZE
901# AND THE JOB SIZE AS COMPUTED BY PYKOTA EITHER USING HARDWARE OR
902# SOFTWARE.
903trustjobsize : yes
904
905# Should we deny duplicate jobs ?
906#
907# A duplicate is a job sent twice (or more) in a row to the same printer
908# by the same user.
909#
910# This can be defined either globally or on a per printer basis
911# The default value is 'no', meaning that duplicate jobs are
912# allowed.
913#
914# NB : if an user prints a job, a second user prints another
915#      job, and the first user prints the first job again,
916#      this is NOT considered as a duplicate since the two
917#      identical jobs printed by the first user are not
918#      one just after the other.
919#
920# Possible values are 'yes', 'no', or any other string.
921# If the string is not recognized as a truth value,
922# it is considered to be a command to launch.
923# PyKota launches the command and parses its standard
924# output. The special keywords 'ALLOW' and 'DENY' are
925# recognized, allowing an external tool to decide if
926# the job is to be allowed or denied.
927#
928# denyduplicates : /usr/bin/myowncommand with some arguments
929# denyduplicates : yes
930denyduplicates : no
Note: See TracBrowser for help on using the browser.